Cyberpower Systems Online S 6000VA/5400W Tower UPS

CyberpowerSKU: OLS6000E

CyberPower Online S 6000 VA / 5400 Watts UPS, Online Double Conversion, Tower, Multifunction LCD Readout, USB & Serial Ports, SNMP Slot, 15 AMP Input, 2 Year Advanced Replacement Wty with 2 Year Internal Battery Wty

Availability:

✅ In Stock at Supplier (ETA: Usually in 1-3 Business Days)

Price:
Sale price$3,436.00

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Estimate shipping

Description

OVERVIEW

CyberPower OLS6000E is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment.

By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 96%.

The product is equipped with a Maintenance Bypass Switch. By flipping the switch, the power supply is safely transferred to utility. This allows service personnel to carry out fast on-site maintenance without having to shut down any connected equipment.

FEATURES:

Online (Double Conversion) UPS Topology
Energy Saving Technology
UPS Parallel Expansion
Generator Compatible
Overload Protection
Maintenance Bypass Switch
Zero Transfer Time
Smart Battery Management (SBM)
External Battery Module (EBM)
Surge and Spike Protection
EMI and RFI Filtration
LCD Status Display
Emergency Power Off (EPO) Port
Power Panel® Management Software
SNMP/ HTTP Remote Management Capability
Tower Form Factor

TYPICAL APPLICATION

Data Closets
NAS & Servers
Home Theater Systems
DVRs/Surveillance Systems
POS Systems
Transportation & Infrastructure
Vehicle/Yacht
Emergency Systems
Electric Lighting
Back Office
Server Room
Data Center

FEATURES FOCUS

Extended Runtime
Extended runtime is critical for most power demanding electronic devices. The installation of CyberPower's external battery modules allows scalable system runtime, guaranteeing higher system availability that ensures clean, uninterrupted power to protected equipment even during a power outage.

Smart Battery Management
Batteries are normally consider as a consumable item that requires replacement on a regular basis. To further prolong battery life span, UPS adopted with Smart Battery Management technology uses a 3-cycle approach and temperature compensation method which efficiently reduces battery maintenance cost and achieves a lower total cost of ownership.

SPECIFICATIONS:

GENERAL


UPS Topology
Online Double Conversion
Energy Saving Technology
Online ECO Mode Efficiency > 96%
Active PFC Compatibility
Yes
Parallel Expansion (Max. Units)
4

INPUT

Generator Compatibility
Yes
Nominal Input Voltage (Vac)
230
Input Voltage Range (Vac)
110 ~ 276
Adjustable Voltage Range (Vac)
0~80% Load for 110 ~ 276 Vac
0~100% Load for 176 ~ 276 Vac
Input Frequency (Hz)
50 ± 5
60 ± 6
Input Frequency Detection
Auto-sensing
Rated Input Current (A)
27.3
Input Power Factor
0.99
Input Connector Type
Hardwire Terminal Block

OUTPUT

Capacity (VA)
6000
Capacity (Watts)
5400
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s) (Vac)
208 ± 1%
220 ± 1%
230 ± 1%
240 ± 1%
Output Voltage Setting
Configurable
On Battery Frequency (Hz)
50 ± 0.1%
60 ± 0.1%
Output Frequency Setting
Configurable
ECO Mode Voltage Tolerance
± 10 %
Overload Protection
Internal Current Limiting , Circuit Breaker , Fuse
Overload Protection (Line Mode)
105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec
Overload Protection (Battery Mode)
105~125% Load for 2 min, 125~150% Load for 30 sec, >150% Load for 1 sec
Overload Protection (Bypass Mode)
125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<2%
Harmonic Distortion (Non-linear Load)
THD<5%
Internal Bypass
Automatic Bypass
Maintenance Bypass
Yes
Outlet(s) - Total
1
Outlet Type
Hardwire Terminal Block x 1
Typical Transfer Time (ms)
0

BATTERY

Runtime at Half Load (min)
18
Runtime at Full Load (min)
7
Typical Recharge Time (Hours)
7
Maximum Charging Current (A)
1
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
User Replaceable
No
Battery Type
Sealed Lead-acid
Single Battery Capacity (AH)
12 V 7 AH
Extended Battery Module (EBM)
BPSE240V47A
Max. EBM Quantity (pcs)
15

SURGE PROTECTION & FILTERING

Surge Suppression (Joules)
445
EMI/RFI Filtration
Yes

MANAGEMENT & COMMUNICATIONS

LCD Panel
Yes
LCD Information Display
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log
LCD Setting & Control
Mode Setting , Alarm Setting , Input & Output , Battery Setting , Fault & Warning , Communication , Event & Log , Security Setting
LED Indicators
Line Mode , Battery Mode , Bypass Mode , UPS Fault
HID Compliant USB Port(s)
1
Serial Port
RS232
Dry Contact (with Relay)
Optional
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault
Power Management Software
PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring
Yes - with optional RMCARD205

PHYSICAL

Form Factor
Tower
Enclosure Construction
Metal
Color
Black

PHYSICAL SIZE - UPS MODULE

Dimensions (WxHxD) (mm.)
260 x 708 x 550
Weight (kg.)
70

PHYSICAL SIZE - BATTERY MODULE

Dimensions (WxHxD) (mm.)
260 x 718 x 550
Weight (kg.)
105

SHIPPING DIMENSIONS

Dimensions (WxHxD) (mm.)
428 x 970 x 720
Weight (kg.)
82

ENVIRONMENTAL

Operating Temperature (°C)
0 ~ 40
Operating Relative Humidity (Non-condensing) (%)
0 ~ 90
Operating Elevation (feet/meters)
≤1000, Load Derated 1% per 100m from 1000m and 2000m
Storage Temperature (°C)
-15 ~ 45
Storage Relative Humidity (Non-condensing) (%)
0 ~ 95
Online Thermal Dissipation (BTU/hr)
1603

CERTIFICATIONS

Certifications
CE
RoHS
Yes

WARRANTY

Product Warranty Period (Year) 2 Battery Warranty Period (Year) 2