Description
Overview
High density, double-conversion on-line power protection with scalable runtime
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Specifications
Output
Output power capacity
1.98kWatts / 2.2kVA
Max Configurable Power (Watts)
1.98kWatts / 2.2kVA
Nominal Output Voltage
230V
Output Voltage Distortion
Less than 2%
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Other Output Voltages
220, 240
Load Crest Factor
3 : 1
Topology
Double Conversion Online
Waveform type
Sine wave
Output Connections
(2) IEC 320 C19 (Battery Backup)
(6) IEC 320 C13 (Battery Backup)
Bypass
Built-in Bypass
Input
Nominal Input Voltage
230V
Input frequency
40 - 70 Hz (auto sensing)
Input Connections
British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
Cord Length
1.83meters
Input voltage range for main operations
50-150 (40% Load), 80 - 150V
Number of Power Cords
1
Other Input Voltages
220, 240
Batteries & Runtime
Battery type
Li-ion
Typical recharge time
4hour(s)
Expected Battery Life (years)
5 - 10
Extendable Run Time
1
Extended Run Options
APC-SMART-UPS-SRT-LI-ION-2200VA-RM-230V-NETWORK-CARD
Communications & Management
Interface Port(s)
RJ-45 Serial, Smart-Slot, USB
Pre-Installed SmartSlot™ Cards
AP9631
Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity
Emergency Power Off (EPO)
Yes
Surge Protection and Filtering
Surge energy rating
432Joules
Physical
Maximum Height
85MM, 8.5CM
Maximum Width
432MM, 43.2CM
Maximum Depth
611MM, 61.1CM
Rack Height
3U
Net Weight
30.5KG
Color
Black
Units per Pallet
12.0
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 (non-condensing) %
Operating Elevation
0-3000meters
Storage Temperature
-20 - 50 °C
Storage Relative Humidity
0 - 95 (non-condensing) %
Storage Elevation
0-15000meters
Audible noise at 1 meter from surface of unit
50.0dBA
Online thermal dissipation
317.0BTU/hr
Protection Class
IP 20
High density, double-conversion on-line power protection with scalable runtime
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Specifications
Output
Output power capacity
1.98kWatts / 2.2kVA
Max Configurable Power (Watts)
1.98kWatts / 2.2kVA
Nominal Output Voltage
230V
Output Voltage Distortion
Less than 2%
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Other Output Voltages
220, 240
Load Crest Factor
3 : 1
Topology
Double Conversion Online
Waveform type
Sine wave
Output Connections
(2) IEC 320 C19 (Battery Backup)
(6) IEC 320 C13 (Battery Backup)
Bypass
Built-in Bypass
Input
Nominal Input Voltage
230V
Input frequency
40 - 70 Hz (auto sensing)
Input Connections
British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
Cord Length
1.83meters
Input voltage range for main operations
50-150 (40% Load), 80 - 150V
Number of Power Cords
1
Other Input Voltages
220, 240
Batteries & Runtime
Battery type
Li-ion
Typical recharge time
4hour(s)
Expected Battery Life (years)
5 - 10
Extendable Run Time
1
Extended Run Options
APC-SMART-UPS-SRT-LI-ION-2200VA-RM-230V-NETWORK-CARD
Communications & Management
Interface Port(s)
RJ-45 Serial, Smart-Slot, USB
Pre-Installed SmartSlot™ Cards
AP9631
Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity
Emergency Power Off (EPO)
Yes
Surge Protection and Filtering
Surge energy rating
432Joules
Physical
Maximum Height
85MM, 8.5CM
Maximum Width
432MM, 43.2CM
Maximum Depth
611MM, 61.1CM
Rack Height
3U
Net Weight
30.5KG
Color
Black
Units per Pallet
12.0
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 (non-condensing) %
Operating Elevation
0-3000meters
Storage Temperature
-20 - 50 °C
Storage Relative Humidity
0 - 95 (non-condensing) %
Storage Elevation
0-15000meters
Audible noise at 1 meter from surface of unit
50.0dBA
Online thermal dissipation
317.0BTU/hr
Protection Class
IP 20
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.